The electrical wire tracer is laid alongside the pipes or lines during installation in order to find them at a later date for safe digging.
Tracer wire for water line installation.
A tracer wire system is only as good as its weakest connection.
The insulation is a high molecular weight and high density polyethylene which is resistant to abrasions crushing chemicals oils and moisture.
They are able to locate the buried pipe quickly and know where it is safe to dig.
Trace wire installation shall be performed in such a manner that allows proper access for connection of line tracing equipment proper locating of wire without loss or deterioration of low frequency 512hz signal for distances in excess of 1 000 linear feet and without distortion of signal caused by multiple wires being installed in close proximity to one another.
Contact with the pipe is allowed but shall be minimized.
Step 2 connect.
Installation install tracer wire along the pipe above or to the side of the pipe.
These two wires are not interchangeable.
Hold the tracer wire at the start of the pipe near the street and fasten it to the pipe by wrapping it with electrical tape.
Trace wire systems must be installed as a single continuous wire except where using approved connectors.
5 steps to installing a tracer wire system step 1 conduct.
Splicing of wire if necessary shall be done in such a way to.
A coated copper clad steel tracer wire of 12 gauge or larger kub item 300362 shall be installed with all buried plastic mains and services.
Tracer wire should not be wrapped around pipe or connectors except at the riser.
Step 3 ground.
Open cut copperhead industries exclusive high strength copper clad steel tracer wire combines the strength and flexibility of fully annealed high carbon steel with the conductivity and corrosion resistance of solid copper.
Choosing copper clad steel tracer wire has.
Step 2 roll out the tracer wire along the pipe taping it to the pipe every 5 feet.
Benefits of tracer wire vs.
Ansi gptc install tracer wire as a single continuous wire.
The first step is selecting your tracer wire.
An example would be install 12 solid copper wire with jacket.
Underground tracer wire is available in sizes 14 through 6 awg in an array of colors depending on the intended use.
Recommended 2 6 separation.
The tracer wire shall be laid within 6 inches of the plastic pipe where practical and directly above if possible.
Proper installation and location to the pipe termination of the wire and connecting the wire properly when splicing or connecting to a service are very important as well.
When you install copperhead tracer wire and complete locating system you can expect value reliability and the best service industry wide.